Product Overview
The X54260 series is a new generation of high-performance data center TOR switches launched by Shenzhen Xallcom Technology Co., Ltd. for high-performance cloud computing, data centers, and high-end park networks. It adopts advanced hardware architecture design and provides the highest switching performance and rich data center business features in the industry.
To meet the demand for resource pooling in cloud computing data centers, the X54260 series supports a rich set of virtualization features such as VSS (Virtual Switching System technology) and data center features like TRILL, SDN, FCoE/FC1, etc. It can be used in conjunction with core data center switches to provide access to over 15,000 10G servers, offering a comprehensive network solution for super-large data centers.
The X54260 series is equipped with an operating system that has independent intellectual property rights. It provides high-performance L2/L3/L4 line-speed switching services and further integrates various network services such as IPv6, MPLS VPN, network security, traffic analysis, and virtualization... It combines various data center high-reliability technologies such as uninterrupted upgrade, uninterrupted forwarding, graceful restart, and redundancy protection to ensure the longest uninterrupted communication capability of the network.
Based on the advanced communication concept of ‘GreenTouch’ and the industry-leading ’Smart@CHIP’ intelligent chip green energy-saving technology, it significantly reduces energy consumption, is low-carbon and environmentally friendly, effectively reduces data center operating costs, and provides a perfect solution for the green and sustainable development of networks.
Product Features
Advanced Hardware Architecture Design With Leading Processing Capabilities
Equipped with high-performance ASIC switch chips and multi-core processors, supporting up to 1.28Tbps switching capacity, meeting the high-performance, high-capacity, high-density, and scalable requirements of data centers
Standard front-to-back heat dissipation design, with flexible selection of airflow direction.
Rich Data Center-Specific Features
VSS(Virtual Switch System)Virtual Cluster Switching Technology
The X54260 series supports innovative VSS virtualization cluster switching technology that can virtualize multiple physical devices into a logical device. The virtual system offers unparalleled performance, reliability, flexibility, and management compared to independent physical devices.
Doubled performance: The virtualized system can fully utilize each link between physical devices, avoiding link blocking by traditional network models’ spanning tree protocols. This maximizes performance and protects existing link investments.
High reliability: Based on advanced distributed processing technology, the logical control plane and business data plane are separated through efficient cross-physical device link aggregation. This provides uninterrupted Layer 3 routing forwarding, avoiding business interruptions caused by single point failures and greatly improving the reliability of the virtual system.
Flexibility: With the X54260 series’ virtual cluster functionality, the distance of the virtual cluster system can be extended up to 80 kilometers. This flexibility breaks the geographical limitations of traditional clustering technologies.
Easy management: The entire virtual system achieves unified management with a single IP. The actual physical devices are transparent to users, simplifying network device and topology management. This significantly improves network operation efficiency and effectively reduces operation and maintenance costs.
Unified Switching
It supports FCoE (FC over Ethernet) technology, solving the heterogeneity problem between LAN networks and FC storage networks. This enables the convergence of computing, data, and storage networks, achieving unified switching.
Data Center-Grade Reliability
Based on the HPS (Hitless Protection System), the key power system adopts redundant design, modular and hot-swappable, supports seamless switching during faults, and does not require business interruption.
Supports protocols like STP/RSTP/MSTP, VRRP, ring network protection, double uplink primary-standby link protection, LACP link aggregation, and other efficient redundancy protection mechanisms.
Supports ISSU (In-Service Software Upgrade) for uninterrupted system upgrades, ensuring continuous data forwarding for users during system upgrades and main control switching.
Ultra-high precision BFD (Bidirectional Forwarding Detection) mechanism, by linking with Layer 2 and Layer 3 protocols, achieves millisecond-level fault detection and service recovery, significantly enhancing the reliability of the network system.
A comprehensive Ethernet OAM (Operations, Administration, and Maintenance) mechanism, Supporting 802.3ah, 802.1ag, and ITU-Y.1731, enables real-time monitoring of the network's operational status, achieving rapid fault detection and localization.
The high-reliability design of both software and hardware meets the 50ms fault recovery time requirement, truly achieving the 5 nines (99.999%) high reliability of core devices.
Rich Business Features
Comprehensive L2 and L3 multicast routing protocols, meeting the access needs of IPTV, multi-terminal HD video surveillance, and HD video conferencing.
A full range of L3 routing protocols with a large routing table capacity, satisfying various types of network interconnection needs, and can form large-scale data center networks, campus networks, enterprise networks, and industry-specific private networks.
Fully Supports Layer 2 and Layer 3 MPLS VPN, enabling the formation of large-scale MPLS VPN core networks, meeting the access requirements of industry-specific VPN users and enterprise VPN users.
Comprehensive IPv6 Solution
Fully Supports the IPv6 protocol suite, including IPv6 neighbor discovery, ICMPv6, Path MTU discovery, DHCPv6, and other IPv6 features.
Supports IPv6-based Ping, Traceroute, Telnet, SSH, ACL, etc., meeting the needs of pure IPv6 network device management and business control.
Supports IPv6 multicast features such as MLD, MLD Snooping, and Supports IPv6 static routes, RIPng, OSPFv3, BGP4+ and other L3 IPv6 routing protocols, providing users with a comprehensive L2 and L3 IPv6 solution.
Supports a variety of IPv4 to IPv6 transition technologies, including: manual IPv6 tunnels, automatic tunnels, 6to4 tunnels, ISATAP tunnels, and other tunneling technologies, ensuring a smooth transition from IPv4 networks to IPv6 networks.
Comprehensive Security Mechanism
Device-level security protection: Advanced hardware architecture design, hardware-implemented message hierarchical scheduling and protection, Supports defense against attacks on the device such as DoS, TCP's SYN Flood, UDP Flood, broadcast storms, and high traffic attacks; Supports command-line hierarchical protection, where different user levels have different management permissions.
Comprehensive security authentication mechanism: Supports IEEE 802.1x, Radius, Tacacs+, etc., providing users with a complete security authentication mechanism.
Enhanced business security mechanisms: Supports plaintext or MD5 authentication for relevant routing protocols, Supports uRPF reverse route lookup technology, effectively controlling unauthorized services; hardware-level deep packet inspection and filtering technology, Supports deep inspection of control messages and data packets, thereby effectively isolating unauthorized data packets and enhancing network system security.
Innovative Green and Environmentally Friendly Design
Embraces the advanced "GreenTouch" concept, promoting energy conservation and environmental protection.
Intelligent power management system: Uses an advanced power system architectural design, achieving efficient power conversion, unique power monitoring, soft start, and other functions, real-time monitoring of the machine's operating status, intelligent adjustments, and deep energy saving.
Intelligent fan management system: Smart fan design, Supports flexible choice of front-to-back/back-to-front airflow, Supports automatic fan speed adjustment, effectively reducing speed, decreasing noise, and extending the fan's lifespan.
Supports energy-efficient Ethernet functionality, complying with the international standard IEEE 802.3az, effectively reducing energy consumption.
Product Specification
Item |
X54260-B-H |
|
Switching Capacity |
2.56Tbps |
|
Package Forwarding Rate |
660Mpps |
|
Power Slot No. |
2 |
|
Fan Slot Number |
4(Inbuilt) |
|
Ports |
24 * 10G SFP+ ports |
|
2 * 100G QSFP ports |
||
Data Center Features |
Supports for VSS virtualization technology Supports for the FCoE technology |
|
MAC Switching |
Supports for static configuration and dynamically learning of MAC addresses Supports to view and clear the MAC addresses Aging time of the MAC address is configurable Supports for limiting MAC address learning numbers Supports the MAC address filtering function Supports configuring black hole MAC table entries Supports IEEE 802.1AE MacSec security control |
|
VLAN |
Supports 4K VLAN table entries Supports GVRP Supports for 1:1 and N: 1 VLAN Mapping Supports for basic QinQ and flexible QinQ features Supports for Private VLAN |
|
STP |
Supports for 802.1D(STP), 802.1W(RSTP), 802.1S (MSTP) Supports for BPDU protection, root protection, and loop protection |
|
Multicast |
Supports for IGMP v1 / v2 / v3 Supports for the IGMP Snooping Supports for the IGMP Fast Leave Supports the multicast group strategy and the number of multicast group limit Supports replication of multicast traffic across VLAN Supports for PIM-SM, PIM-DM |
|
IPv4 |
Static routing, RIP v1 / v2, OSPF, BGP, IS-IS, BEIGRP are supported Supports strategy routing Supports equivalent routing to achieve load balancing Supports for BFD for OSPF, and BGP |
|
IPv6 |
Supports for ICMPv6, DHCPv6, ACLv6, and IPv6 Telnet Supports the IPv6 neighbor discovery Supports for Path MTU discovery Supports for MLD V1/V2 Supports MLD Snooping Supports IPv6 static routing, RIPng, OSPFv3, and BGP4+ Supports manual tunnel, ISATAP tunnel, and 6to4 tunnel |
|
MPLS VPN |
Supports LDP protocol Supports MCE Supports the P / PE functional requirements of the MPLS VPN Supports for the MPLS TE Supports for the MPLS OAM |
|
QoS |
Supports traffic classification based on L2/L3/L4 protocol header fields Supports for CAR traffic restrictions Supports 802.1P/DSCP priority remarking Supports the queue scheduling methods, such as SP, WRR, and SP + WRR Supports congestion avoidance mechanisms such as Tail-Drop and WRED Supports for flow supervision and flow shaping Support for Ingress and Egress ACL, matching L2, L3, L4, and IP quintuples, copying, forwarding, and discarding. Support for Hash-based source and destination load balancing, ensuring the integrity of traffic output sessions |
|
Safety Features |
Supports L2 / L3 / L4 based ACL flow identification and filtering safety mechanism Supports avoidance of DDoS attack, TCP SYN Flood attack, UDP Flood attack, etc Supports the suppression function of multicast, broadcast and unknown single broadcast text Supports port isolation Supports for port security, IP + MAC + port binding Supports for DHCP Snooping, and DHCP Option 82 Supports for IEEE 802.1x authentication Supports for Radius, Tacacs + authentication Supports uRPF Supports command line hierarchical protection |
|
Reliability |
Supporting for power supply 1 + 1 backup is optional Supports static / LACP link aggregation and link aggregation across business cards Supports for ring network protection like EAPS, ERPS Supports Hot Standby Protocol like HSRP, VRRP Supports for GR for OSPF, and BGP Supports for BFD for OSPF, and BGP Supports ISSU (In-Service Software Upgrade) for uninterrupted system upgrades |
|
Management and Maintenance |
Supports for Console, Telnet, and SSH 2.0 Supports for ZTP(zero-touch provisioning) Supports for browser-based WEB management Supports for SNMP v1 / v2 / v3 Supports the TFTP way of the file upload, download and management Supports for RMON event history record Supports traffic monitoring technology like sFLOW for traffic statistical analysis |
|
Green Energy Saving |
Supports for IEEE 802.3az green energy efficiency Ethernet |
|
Environmental Requirements |
Working temperature / humidity: -10°C ~50°C, 10% -90% no condensation Storage temperature / humidity: -20°C ~70°C; 5% -95% no condensation |
|
Power Supply |
AC:100V-240V,50Hz±10% DC:-36V~-72V |
|
Dimension |
442.5(L)×300(W)×44.5(H)mm |