Welcome to Shenzhen Xallcom Technology Co.,Ltd.
5-series:Managed Commercial Switch

Home  -  Products  -  5-series:Managed Commercial Switch   -  

X54280-B-H  Data Center Core Switch Spec
X54280-B-H Data Center Core Switch Spec

The X54280-B-H is a next-generation high-performance data center all-gigabit switch launched by Shenzhen Xallcom Technology Co., Ltd. for high-performance cloud computing, data centers, and high-end campus networks. It adopts advanced hardware architecture design and provides the industry's highest switching performance and a rich set of data center-specific features.


To meet the demand for resource pooling in cloud computing data centers, the X54280-B-H Supports a rich set of VSS (Virtual Switching System) virtualization features and data center-specific features like TRILL, SDN, FCoE/FC, etc. In combination with Xallcom's X5532 core data center switch, it can accommodate the connection of more than 15,000 10G servers, providing a comprehensive network solution for large-scale data centers.


While offering high-performance L2/L3/L4 wire-speed switching services, the X54280-B-H further integrates various network services like IPv6, MPLS VPN, network security, traffic analysis, and virtualization, coupled with uninterrupted upgrades, uninterrupted forwarding, graceful restarts, and redundant protection. All these ensure the longest uninterrupted communication capability for the network.


The advanced "GreenTouch" concept and the industry-leading "Smart@CHIP" intelligent chip energy-saving technology ensure that the device's power consumption is less than 200W. This significantly reduces energy consumption, emphasizes Eco-friendliness, effectively reduces data center operating costs, and provides a perfect solution for the sustainable development of networks.

Advanced hardware architecture design with leading processing capabilities

Equipped with high-performance ASIC switch chips and multi-core processors to meet the high-performance, high-capacity, high-density, and scalability requirements of data centers.

Standard front-to-back heat dissipation design, with flexible selection of airflow direction.

Rich data center-specific features

Supports VSS virtualization cluster switching technology, which can virtualize multiple physical devices into one logical device. This offers unmatched performance, reliability, flexibility, and management compared to independent physical devices.

 Doubling of performance: The virtualization system can fully utilize every link between physical devices, avoiding blockages on links by the traditional network model's spanning tree protocol. This makes the most out of resources, doubling performance, and maximally protecting the original link investment.

High reliability: Based on advanced distributed processing technology, it achieves a separation of logical control and business data planes, ensuring uninterrupted L3 routing and avoiding single-point failures, significantly enhancing the reliability of the virtual system.

Flexibility: Through the virtual cluster function, the distance of the virtual cluster system can be extended to 80KM, offering flexibility and convenience, breaking the geographical limitations of traditional cluster technology.

Ease of management: The entire virtual system achieves unified management with a single IP, making the actual physical devices transparent to users. This simplifies the management of network devices and topology, greatly enhancing network operational efficiency and effectively reducing operational maintenance costs.

L2 technology: Supports TRILL/SPB protocols, allowing for the construction of a large Layer 2 network in the data center. This simplifies and flattens the network structure, meeting the needs of large-scale server access in data centers

Unified switching: Supports FCoE (FC over Ethernet) technology, addressing the heterogeneity issues between LAN networks and FC storage networks, thereby achieving the integration of computing, data, and storage networks, realizing unified switching.

SDN: Supports SDN (Software Defined Network) for high-level network virtualization and centralized management.

Data center-grade reliability

 Based on the HPS (Hitless Protection System) uninterrupted protection system, key components of the X54280-B-H, such as the power system and fan system, adopt redundant designs. All system modules are hot-swappable, Supportsing seamless switching during failures without the need for manual intervention.

Supports protocols like STP/RSTP/MSTP, VRRP, ring network protection, ual uplink primary-standby link protection, LACP link aggregation, and other efficient redundancy protection mechanisms.

Supports ISSU (In-Service Software Upgrade) for uninterrupted system upgrades, ensuring continuous data forwarding for users during system upgrades and main control switching.

Ultra-high precision BFD (Bidirectional Forwarding Detection) mechanism, by linking with Layer 2 and Layer 3 protocols, achieves millisecond-level fault detection and service recovery, significantly enhancing the reliability of the network system.

 A comprehensive Ethernet OAM (Operations, Administration, and Maintenance) mechanism, Supportsing 802.3ah, 802.1ag, and ITU-Y.1731, enables real-time monitoring of the network's operational status, achieving rapid fault detection and localization.

The high-reliability design of both software and hardware meets the 50ms fault recovery time requirement, truly achieving the 5 nines (99.999%) high reliability of core devices.

Rich Business Features

Comprehensive L2 and L3 multicast routing protocols, meeting the access needs of IPTV, multi-terminal HD video surveillance, and HD video conferencing.

 A full range of L3 routing protocols with a large routing table capacity, satisfying various types of network interconnection needs, and can form large-scale data center networks, campus networks, enterprise networks, and industry-specific private networks.

Fully Supports Layer 2 and Layer 3 MPLS VPN, enabling the formation of large-scale MPLS VPN core networks, meeting the access requirements of industry-specific VPN users and enterprise VPN users.

Comprehensive IPv6 solution

Fully Supports the IPv6 protocol suite, including IPv6 neighbor discovery, ICMPv6, Path MTU discovery, DHCPv6, and other IPv6 features.

Supports IPv6-based Ping, Traceroute, Telnet, SSH, ACL, etc., meeting the needs of pure IPv6 network device management and business control.

Supports IPv6 multicast features such as MLD, MLD Snooping, and Supports IPv6 static routes, RIPng, OSPFv3, BGP4+ and other L3 IPv6 routing protocols, providing users with a comprehensive L2 and L3 IPv6 solution.

 Supports a variety of IPv4 to IPv6 transition technologies, including: manual IPv6 tunnels, automatic tunnels, 6to4 tunnels, ISATAP tunnels, and other tunneling technologies, ensuring a smooth transition from IPv4 networks to IPv6 networks.

Comprehensive security mechanism

Device-level security protection: Advanced hardware architecture design, hardware-implemented message hierarchical scheduling and protection, Supports defense against attacks on the device such as DoS, TCP's SYN Flood, UDP Flood, broadcast storms, and high traffic attacks; Supports command-line hierarchical protection, where different user levels have different management permissions.

Comprehensive security authentication mechanism: Supports IEEE 802.1x, Radius, Tacacs+, etc., providing users with a complete security authentication mechanism.

Enhanced business security mechanisms: Supports plaintext or MD5 authentication for relevant routing protocols, Supports uRPF reverse route lookup technology, effectively controlling unauthorized services; hardware-level deep packet inspection and filtering technology, Supports deep inspection of control messages and data packets, thereby effectively isolating unauthorized data packets and enhancing network system security.

Innovative green and environmentally friendly design

Embraces the advanced "GreenTouch" concept, promoting energy conservation and environmental protection.

 Intelligent power management system: Uses an advanced power system architectural design, achieving efficient power conversion, unique power monitoring, soft start, and other functions, real-time monitoring of the machine's operating status, intelligent adjustments, and deep energy saving.

Intelligent fan management system: Smart fan design, Supports flexible choice of front-to-back/back-to-front airflow, Supports automatic fan speed adjustment, effectively reducing speed, decreasing noise, and extending the fan's lifespan.

Supports energy-efficient Ethernet functionality, complying with the international standard IEEE 802.3az, effectively reducing energy consumption.

 

Item

X54280-B-H

Switching Capacity

640Gbps

Package Forwarding Rate

480Mpps

Power Slot Number

2

Fan Slot Number

4

Ports

24 * 10G SFP + ports

4 * 100G/40G QSFP+ ports (QSFP28 packaging, compatible with 40G QSFP+ or expandable to 4x10GE)

Data Center Features

Supports for BVSS virtualization technology

Supports for TRILL / SPB L2+ technology

Supports for the FCoE technology

Supports SDN

MAC Switching

Supports for static configuration and dynamically learning of MAC addresses

Supports to view and clear the MAC addresses

Aging time of the MAC address is configurable

Supports for limiting MAC address learning numbers 

Supports the MAC address filtering function

Supports configuring black hole MAC table entries

VLAN

Supports 4K VLAN table entries

Supports GVRP

Supports for 1:1 and N: 1 VLAN Mapping

Supports for basic QinQ and flexible QinQ features

Supports for Private VLAN

STP

Supports for 802.1D(STP), 802.1W(RSTP), 802.1S (MSTP)

Supports for BPDU protection, root protection, and loop protection

Multicast

Supports for IGMP v1 / v2 / v3

Supports for the IGMP Snooping

Supports for the IGMP Fast Leave

Supports the multicast group strategy and the number of multicast group limit

Supports replication of multicast traffic across VLAN

Supports for PIM-SM, PIM-DM

IPv4

Static routing, RIP v1 / v2, OSPF, and BGP are supported

Supports strategy routing

Supports equivalent routing to achieve load balancing

Supports for BFD for OSPF, and BGP

IPv6

Supports for ICMPv6, DHCPv6, ACLv 6, and IPv6 Telnet

Supports the IPv6 neighbor discovery

Supports for Path MTU discovery

Supports for MLD, MLD Snooping

Supports IPv6 static routing, RIPng, OSPFv3, and BGP 4 +

Supports manual tunnel, ISATAP tunnel, and 6to4 tunnel

MPLS VPN

Supports LDP protocol

Supports MCE

Supports the P / PE functional requirements of the MPLS VPN

Supports for the MPLS TE

Supports for the MPLS OAM

QoS

Supports traffic classification based on L2/L3/L4 protocol header fields

Supports for CAR traffic restrictions

Supports 802.1P/DSCP priority remarking

Supports the queue scheduling methods, such as SP, WRR, and SP + WRR

Supports congestion avoidance mechanisms such as Tail-Drop and WRED

Supports for flow supervision and flow shaping

Safety Features

Supports L2 / L3 / L4 based ACL flow identification and filtering safety mechanism

Supports avoidance of DDoS attack, TCP SYN Flood attack, UDP Flood attack, etc

Supports the suppression function of multicast, broadcast and unknown single broadcast text

Supports port isolation

Supports for port security, IP + MAC + port binding

Supports for DHCP Snooping, and DHCP Option 82

Supports for IEEE 802.1x authentication

Supports for Radius, Tacacs + authentication

Supports uRPF

Supports command line hierarchical protection

Reliability

Supports for power supply 1 + 1 backup

Supports hot-swappable power supply and fan

Supports static / LACP link aggregation and link aggregation across devices

Supports for EAPS and other ring network protection

Supports VRRP

Supports for Ethernet OAM 802.3ah/802.1ag/ITU-Y.1731

Supports for GR for OSPF, and BGP

Supports for BFD for OSPF, and BGP

Supports ISSU (In-Service Software Upgrade) for uninterrupted system upgrades

Supports for NTP clock synchronization

Management and Maintenance

Supports for Console, Telnet, and SSH

Supports for SNMP v1 / v2 / v3

Supports the TFTP way of the file upload, download and management

Supports RMON

Supports sFLOW and Netflow for traffic statistical analysis

Green Energy Saving

Supports for IEEE 802.3az green energy efficiency Ethernet

Environmental Requirements

Working temperature / humidity: 0°C -50°C, 10% -90% no condensation

Storage temperature / humidity: -20°C -70°C; 5% -95% no condensation

Power Supply

AC100V-240V 50Hz±10%

DC-36V~-72V

Dimension

442.5(L)×404(W)×44(H)mm, 1U


Previous:
Next:X54260-B-H Data Center Tor Switch
Copyright 2024 Shenzhen Xallcom Technology Co., Ltd. All Rights Reserved.
Add: 3/F, No.220-1 of Niucheng Road, Xili Street, Nanshan District, Shenzhen, Guangdong, China
Tel: +86-755-8605 9338  Fax: +86-755-8605 9328
E-mail: info@xallcom.com
Design By:www.66168.net